MEDCAPTAIN SYS-6010A infusion pump with drop-sensor support
Volumetric infusion pump with touchscreen controls, a motorised door and adjustable occlusion monitoring. Supports multiple delivery modes, bolus, KVO and drop-sensor connection.
Specifications
- Pump type
- Volumetric peristaltic
- Display
- 2.4-inch TFT touchscreen
- Infusion rate
- 0.1–1200 ml/h; the permitted limit depends on the configured infusion set
- Rate increment
- 0.01 ml/h in the range 0.10–99.99; 0.1 ml/h in the range 100–999.9; 1 ml/h in the range 1000–1200
- Volume to be infused, VTBI
- 0.1–9999 ml
- KVO
- 0.1–5 ml/h
- Bolus
- Manual, rapid preset-volume, automatic
- Occlusion monitoring
- 11 levels, 225–975 mmHg
- Air monitoring
- Adjustable bubble-detection threshold
- Log
- Up to 2000 events
- Mains power supply
- 100–240 V, 50/60 Hz
- External DC power supply
- 12 V, 1 A
- Backup power
- Internal rechargeable battery
- Dimensions, W × H × D
- 100 × 230 × 190 mm
Description
MEDCAPTAIN SYS-6010A is intended for controlled intravenous delivery of fluids and medicinal solutions in a healthcare facility. The peristaltic mechanism works with disposable infusion sets whose compatibility with the pump must be verified. Before first use of a new set brand, appropriate configuration and accuracy verification are required.
The 2.4-inch colour TFT screen supports touch controls, brightness adjustment and automatic locking. The motorised door simplifies tubing installation. Air and pressure sensors monitor the infusion line; a separate clamp is intended to prevent free flow.
The model supports rate, time, patient-weight, step-sequence, loading-dose, trapezoidal-profile and drip modes. Manual and automated bolus options are provided, along with KVO to maintain venous-access patency. Audible and visual alarms indicate occlusion, air in the tubing, an open door, end of delivery and power problems.
The drop sensor connects as a separate accessory. The pump stores an event log for tracking operation; if external power is lost, it automatically switches to the internal rechargeable battery.
For operation by trained medical personnel according to the instructions for the specific revision. Use only infusion sets approved for the pump; alarms do not replace patient observation.
Video, certificates, manuals