Test version of the new MedBoom site
Catalog
Brand: MEDCAPTAINSKU: R10825

MEDCAPTAIN SYS-6010A infusion pump with drop-sensor support

Reviews
Availability on request
45 000 ₴

Volumetric infusion pump with touchscreen controls, a motorised door and adjustable occlusion monitoring. Supports multiple delivery modes, bolus, KVO and drop-sensor connection.

Equipment manager consultation+38 (050) 183-83-83

Specifications

Pump type
Volumetric peristaltic
Display
2.4-inch TFT touchscreen
Infusion rate
0.1–1200 ml/h; the permitted limit depends on the configured infusion set
Rate increment
0.01 ml/h in the range 0.10–99.99; 0.1 ml/h in the range 100–999.9; 1 ml/h in the range 1000–1200
Volume to be infused, VTBI
0.1–9999 ml
KVO
0.1–5 ml/h
Bolus
Manual, rapid preset-volume, automatic
Occlusion monitoring
11 levels, 225–975 mmHg
Air monitoring
Adjustable bubble-detection threshold
Log
Up to 2000 events
Mains power supply
100–240 V, 50/60 Hz
External DC power supply
12 V, 1 A
Backup power
Internal rechargeable battery
Dimensions, W × H × D
100 × 230 × 190 mm

Description

MEDCAPTAIN SYS-6010A is intended for controlled intravenous delivery of fluids and medicinal solutions in a healthcare facility. The peristaltic mechanism works with disposable infusion sets whose compatibility with the pump must be verified. Before first use of a new set brand, appropriate configuration and accuracy verification are required.

The 2.4-inch colour TFT screen supports touch controls, brightness adjustment and automatic locking. The motorised door simplifies tubing installation. Air and pressure sensors monitor the infusion line; a separate clamp is intended to prevent free flow.

The model supports rate, time, patient-weight, step-sequence, loading-dose, trapezoidal-profile and drip modes. Manual and automated bolus options are provided, along with KVO to maintain venous-access patency. Audible and visual alarms indicate occlusion, air in the tubing, an open door, end of delivery and power problems.

The drop sensor connects as a separate accessory. The pump stores an event log for tracking operation; if external power is lost, it automatically switches to the internal rechargeable battery.

For operation by trained medical personnel according to the instructions for the specific revision. Use only infusion sets approved for the pump; alarms do not replace patient observation.